The Grenfell Tower fire on June 14, 2017, was one of the deadliest residential building fires in modern UK history, claiming 72 lives and highlighting critical failures in fire safety regulations. One of the major concerns raised was the performance of fire doors, which significantly contributed to the spread of smoke and fire instead of containing it as intended.
This tragedy prompted urgent scrutiny and led to fundamental changes in UK fire door compliance standards, enforcement, and accountability.
This article will explore how the Grenfell Tower incident exposed serious weaknesses in fire door safety, examine the regulatory changes introduced in response, and discuss the actions that facilities managers and building owners must take to ensure compliance.

1. Fire Door Failures at Grenfell Tower
Fire doors are a critical component of passive fire protection, designed to contain fire and smoke, protect escape routes, and allow safe evacuation. However, post-Grenfell investigations revealed several significant failures:
1.1 Fire Doors Did Not Provide the Required Fire Resistance Â
Investigations conducted by the Metropolitan Police and fire safety experts found that many flat entrance fire doors failed within 15 minutes, even though they were rated for 30 minutes of fire resistance. This raised serious concerns regarding fire door manufacturing, testing, and certification processes.
1.2 Smoke Spread Was Not Contained Â
Smoke inhalation was the leading cause of fatalities during the Grenfell fire. The failure of fire doors to close properly due to missing self-closing devices or defective seals allowed toxic smoke to spread rapidly throughout the building.
1.3 Lack of Fire Door Maintenance and Inspections Â
Survivor testimonies and post-fire assessments indicated that the fire doors in Grenfell Tower had not been properly maintained or regularly inspected. This lack of enforcement for routine fire door checks meant that defects went unnoticed, contributing to the failure of compartmentation.
Â
2. The Regulatory Changes Introduced Post-Grenfell
The Grenfell Tower tragedy revealed significant weaknesses in fire door regulations, prompting substantial changes in compliance standards. In response, the UK government has implemented new fire safety measures to improve fire door performance, accountability, and maintenance.
2.1 Introduction of the Fire Safety (England) Regulations 2022
Effective January 2023, these regulations mandate fire door checks in multi-occupancy residential buildings. Key requirements include:
- Quarterly fire door checks in common areas for buildings over 11 metres tall.
- Annual fire door inspections for flat entrance doors.
- Clear communication with residents regarding the importance of fire doors and overall fire safety measures.
These changes require building owners and managers to ensure fire doors are regularly inspected, properly maintained, and fully functional.
2.2 Enhanced Fire Door Testing and Certification
In the wake of the Grenfell incident, fire door manufacturers are now subject to stricter testing procedures:
- All fire doors must be tested from both sides to guarantee consistent fire resistance.
- Random sample testing has been introduced to prevent low-quality products from reaching the market.
- Independent third-party certification is now encouraged to promote accountability in fire door manufacturing.
As a result, facilities managers must only acquire fire doors from certified manufacturers and ensure that up-to-date testing documentation is obtained before installation.
2.3 The Building Safety Act 2022 and New Accountability Measures
The Building Safety Act 2022 ushered in a new era of accountability for fire safety compliance. Significant changes include:
- Establishing the Building Safety Regulator, which enforces stricter fire safety laws.
- The designation of a 'Responsible Person' (RP), who is legally accountable for fire door maintenance and compliance.
- Stricter penalties for non-compliance, including unlimited fines and potential imprisonment for negligence.
Facilities managers and landlords must now actively document and demonstrate that fire door checks and maintenance are conducted in accordance with legal requirements.
2.4 What Facilities Managers of Multi-Occupied Buildings Over 11 Metres in Height Must Do to Stay Compliant
To ensure adherence to post-Grenfell fire door safety regulations, facilities managers should implement the following best practices:
-Â Â Â Â Â Â Â Carry Out Quarterly Inspections of Communal Fire Doors
Check doors, seals, and self-closing devices.
Address any defects or damage promptly.
-Â Â Â Â Â Â Â Conduct Annual Inspections of Flat Entrance Doors
Confirm that doors meet the required fire-resistance standards.
Keep written records of inspections.
-Â Â Â Â Â Â Â Use Competent, Certified Professionals
Inspections must be carried out by qualified individuals.
Maintain logs of all findings, repairs, and maintenance.
2. Train Staff and Residents on Fire Door Safety
  - Educate residents about the dangers of propping fire doors open.
  - Train maintenance teams to identify defects, such as worn seals, faulty closers, or gaps.
  - Display clear signage reminding occupants of their responsibilities regarding fire doors.
3. Keep Accurate Records of Fire Door Compliance
  - Maintain a digital log documenting all inspections and repairs related to fire safety.
  - Store certification documents for all installed fire doors.
  - Be prepared to present inspection records to fire safety authorities upon request.
4. Ensure All Fire Doors Meet the Latest Standards
  - Verify that all fire doors are third-party certified.
  - Use fire doors tested from both sides to ensure maximum protection.
  - Ensure proper installation by certified professionals to prevent any performance failures.
The Lasting Impact of Grenfell on Fire Door Compliance
The Grenfell Tower fire marked a turning point in UK fire safety, revealing critical fire door regulations, testing, and maintenance failures. The reforms implemented in the aftermath of this tragedy have led to:
- Stronger compliance enforcement: Fire door inspections are now a legal requirement in multi-occupancy buildings.
- Tighter manufacturing regulations: Fire doors must undergo stricter testing and certification processes.
- Greater accountability: Introducing the ‘Responsible Person’ ensures that someone is legally accountable for fire door maintenance.
For facilities managers, compliance is no longer optional; it is mandatory. Neglecting fire door safety risks fines and legal action and, more importantly, endangers lives.
Â

Let's wrap this up
The Grenfell Tower fire served as a stark reminder that fire doors are not merely building features but life-saving barriers. Inadequate maintenance of fire doors, poor manufacturing standards, and a lack of regulatory oversight contributed to the disaster's scale.
In response, fire door compliance standards have been transformed, with new legal obligations that facilities managers and property owners must follow. Fire doors only function effectively if properly installed, regularly inspected, and consistently maintained.
By taking a proactive approach to fire door compliance, we can help ensure that a tragedy like Grenfell never occurs again.